When (X1~X7) terminal of the definition of "FWD" trigger once,motor will forwardly run.
When (X1~X7) terminal of the definition of "REV" trigger once,motor will reversely run.
Xi is Terminal control functions of (X1~X7) terminal of the definition of 3-wire control,if
state is OFF,inverter stop running.
Note: In 2-wire control mode,When produced by other sources halt instruction and
make the inverter stopping,the inverter will not run in following situation even if FWD/REV
terminal is enabled.Inverter will not run after the stop order to disappear.If you want to
make the inverter running, terminal of the definition of "FWD" or "REV" need trigger again.
Code
F5.01
F5.02
F5.03
F5.04
F5.05
F5.06
F5.07
Fig.6-12 3-wire control mode2
Name
Multifunction input terminal 1(X1)
Multifunction input terminal 2(X2)
Multifunction input terminal 3(X3)
Multifunction input terminal 4(X4)
Multifunction input terminal 5(X5)
Multifunction input terminal 6(X6)
Multifunction input terminal 7(X7)
84
Setting Range
0ÿ^400 10
0ÿ^400 20
0ÿ^400 70
0ÿ^400 00
0ÿ^400 00
0ÿ^400 00
0ÿ^400 00