This function only takes effect if run command source is terminal control.
0:Terminal running command is invalid,when power is on,inverter will not start even if
FWD/REV terminal is active,until FWD/REV terminal disabled and enabled again.
1:Terminal running command is valid,when power on and FWD/REV terminal is
active,inverter will start automatically.
Note:This function may cause the inverter restart automatically,please use it with
cautious.
Code
F1.14
The waiting time of restart when power is on.
6.3 F2 Group: Motor parameters
Code
F2.00
0:G model:Applicable to constant torque load.
1:P model:Applicable to constant power load.
Inverters apply the manner of G/P unification,which means the power of the motor used
in G type is lower than the power of the motor used in P type for one gear.
The Default of the inverter is G model.If P model is selected,it is necessary to set the
Code to 1 and reset the motor parameters of F2.
Code
Restart waiting time when power on
Inverter mode
Name
Name
Name
71
Setting Range
0ÿ^10 00
Setting Range
0ÿ^10 Depend on
model0
Setting Range