Note:Do not change these parameters.

6.4 F3 Group: Vector control

Code
F3.00
F3.01
F3.02
F3.03
F3.04
F3.05
The above parameters are only valid for vector control.ASR PI parameters is decided
by F3.00 and F3.01 when output frequency is less than F3.02.ASR PI parameters is
decided by F3.03 and F3.04 when output frequency is greater than F3.05.When output
frequency is between F3.02 and F3.05,ASR PI parameters obtained by two groups of
parameters of the linear change,please refer to following figure.
Name
ASR proportional gain 1
ASR integral time 1
ASR switching point 1
ASR proportional gain 2
ASR integral time 2
ASR switching point 2
Fig.6-5 PI parameter diagram
73
Setting Range
1ÿ^30000 10000
1ÿ^80000 3000
0.00Hzÿ^F3.050 5.00Hz0
1ÿ^30000 8000
1ÿ^30000 2000
F3.02ÿ^F0.070 10.00Hz0