Craftsman G10-0R7G-2SB Manual page 19

Table of Contents

Advertisement

Termina
Type
l
Analog
+10V
input
AI1
GND
Analog
AO1
output
GND
Digital
X1
input
X2
X3
X4
COM
Digital
Y1
output
COM
Name
+10V
power
supply
Analog input 1
(reference
ground:GND)
Common terminal
of analog signal
Analog output 1
Common terminal
of analog signal
Multifunction
input terminal
Common
ground
terminal for digital
signal
Open collector
output port
Common
ground
terminal for digital
signal
19
Function description
Provide +10V power supply for external
units,
with maximum output current of 10mA.
It is generally used as the operating
power
supply for the external potentiometer.
Analog input, 0~10V/ 0~20mA, switched
by J4(AI1) .
Common terminal of analog input and
output signal
Provide voltage or current output
which can be switched by J1(AO1).
Output range: 0~10V/ 0~20mA
Common terminal of analog input and
output signal
Digital signal input, The common
terminal is COM. Customers could use
parameter F5.01~F5.07 to set the
function. While using these terminals,
pls short þb24V and PW.
state Xn and COM are interlinked, Xn
low level
effectively.
Input voltage range: 9~30V
Input impedance: 3.3kΩ
Open collector output terminal, common
terminal For COM, the function can be
set by Code F6.02.
Terminal valid

Advertisement

Table of Contents
loading

Table of Contents