PID feedback
PIDE
fault
Braking unit
bCE
fault
Time reach of
END
Default
Electronic
OL3
thermal
overload
Keyboard
PCE
connect fault
Parameters
UPE
upload error
Parameters
DNE
download error
SC
Short circuit
1.PID feedback offline.
2. PID feedback source
disappear
disappear.
1.Braking circuit fault or
damage to the braking
pipes.
2.The external braking
resistor is a little low.
Trial time arrival
1.The temperature sensor
wiring is loose
2.The motor temperature
is too high.
Keyboard wire fault.
1.The keyboard and
control panel cable is too
longÿ the parameter is
disturbed while
transmission
2.In the download process
, keyboard save data does
not match the data with
inverter.
1. Acc time is too short.
2.IGBT module is
damaged.
3.Electromagnetic disturb.
4.Output line is short
circuit to the earth.
133
1.Check the PID feedback signal
wires.
2.Check PID feedback source.
1.
Check the braking unit and
change new braking pipes.
2.
Increase braking resistence.
Using parameter initialization
function to remove record
information.
1.Check the temperature sensor
wiring and troubleshooting.
2.Reduce carrier frequency or
other cooling measures to
cooling the motor.
Replace keyboard wire.
1.Shorten the keyboard and
control panel wire to reduce EMI.
2. Before the download process ,
make sure whether the keyboard
saved data are matching with
inverter.
1.Prolong Acc time properly.
2.Check periphery equipment
and restart after fault eliminating.
3.Ask for service.