$` Inspect whether the output side of inverter is short circuit. If yes, ask for service.
$aInspect whether between the motor wires is short circuit or the motor wires is grounded.
If yes,please solve the problem.
$bIf trip happens occasionally and the distance between motor and inverter is too far, it is
recommended to install output AC reactor.
$cAfter fault protection, remove faults, and press the STOP/RESET key to reset the fault ,
and then restart inverter.
$dAfter removing fault,cut off the inverter power source,after all the LED lights on the
inverter extinguish,turn on the inverter power source,then start inverter.
$eWhen the above methods cannot make the inverter be used normally, please record the
failure code on the keyboard, inverter model and series number,then contact our
company technical engineer to solve