Code
F8.21
F8.22
If function of output terminal is set as preset count reached, when the count value
reaches preset count value (F8.22), it will output an ON-OFF signal. Inverter will clear the
counter and restart counting.
If function of output terminal is set as specified count reached,when the count value
reaches specified count value (F8.21), it will output an ON-OFF signal until the count
value reaches preset count value (F8.22). Inverter will clear the counter and restart
counting.
Note:
● Specified count value (F8.21) should not be greater than preset count value (F8.22).
● Output terminal can be R01, R02 or HDO.
This function is shown as following figure:
Fig.6-20 Preset and specified count value reached diagram
Code
F8.23
0:the function is invalid
Fig.6-19 Frequency arriving detection diagram
Specify the counter value
Setting counter value
Overmodulation
Name
Name
105
Setting Range
0~655300 00
0~655300 00
Setting Range