1.
Apply thread sealant to all non-swivel pipe
threads.
Apply anti-seize to threads.
Torque to 60 +/-5 ft-lb (81.3 +/- 6.7 N•m)
with pot pressurized.
Torque to 15 +/-2 ft-lb (20.3 +/- 2.7 N•m)
34
All manuals and user guides at all-guides.com
Apply anti-seize to enclosure mounting
studs.
Torque to 25–30 ft-lb (34–40.6 N•m)
The handway gasket must be installed
centered and flat on the handway cover.
Apply anaerobic sealant to threads.