7. Add 10 gallons (30 liters) of fresh water
to the pot. Add abrasive material (see
Technical Specifications, page 67
information).
8. Close the pot dump valve (J).
9. Use a garden hose or the rinse hose to wash the
abrasive into the pot and clear any abrasive from
the pop-up and gasket.
Make sure water is above the pop-up seal and
pop-up seal is closed. Failure to do so before
pressurizing the pot can result in serious injury
to the operator.
10. When the water level is above the pop-up gasket,
rotate the handle to release the pop-up pin.
3A3489E
All manuals and user guides at all-guides.com
for capacity
11. Turn the selector valve to BLAST.
12. Engage the blast control switch and set the blast
air pressure to a maximum of 175 psi (12.06 bar,
1.2 MPa).
NOTE: Do not increase directly to blast pressure.
NOTE:
NOTE:
Always set below the desired pressure, then
increase to the actual setpoint.
13. Open the abrasive ball valve (M).
Operation
15

Advertisement