A.8

Diagnostics and parameterization

The Service Tool and the Sidoor User Software can be used equally well for diagnostics and
setting the parameters
These tools are optionally available (see Appendix Order nos. of the individual parts
(Page 28)).
The Service Tool and the USB adapter for the Software Kit (Sidoor User Software) can be
connected to X102 on the controller with the associated cable.
The tool keys and buttons have identical inscriptions and functions.
Parameters can be changed in the "MAIN MENU QUICK ADJUSTMENT → Parameter Setting"
and in the "MAIN MENU TOTAL ADJUSTMENT → Profile Parameter" menus.
The desired parameter is selected with the
with the Return key
The parameter value can then be increased or decreased by pressing the corresponding key
(see above).
The value is accepted by pressing the Return key again.
Elevator door drive AT12
Equipment Manual, 06/2020, A2B00086683-AD
Enter key, jumps to the next menu below
Escape key, jumps back to the menu above
Menu selection key, increases a parameter value
Menu selection key, decreases a parameter value
(parameter value flashes).
A.8 Diagnostics and parameterization
or the
key, and activated for the setting
Appendix