Siemens SIDOOR AT12 System Manual page 18

Elevator door drive
Hide thumbs Also See for SIDOOR AT12:
Table of Contents

Advertisement

3. Plug in the X204 power plug (supply voltage is switched off).
4. Press and hold down the learn run button (S501) .
5. Switch on the supply voltage.
6. Keep the learn run button (S501) pressed until the door moves (learn run has started).
During the learn run, the door is opened about 10 cm, and closed once or twice at creep
speed.
The friction of the door system is then determined by opening and closing the door once
through a range of 25 cm at creep speed.
The door then opens and closes through its complete range of movement at reduced speed.
After the door has opened about 10 cm, it passes through a short acceleration ramp to
determine the weight of the door.
In the "CLOSED" position, the door parameters and the determined door width are saved.
During the learn run and while the parameters are being saved, LED H501 flashes green.
When saving has finished, the LED shows a steady green light.
7. The door can now be completely opened by briefly pressing the learn run button. Pressing
the button again, when the door is in the end position "Open", closes the door completely.
8. Switch off mains supply
9. Connect the cable for control signals to the X101 connector as shown in the circuit diagram
(see Appendix Terminal circuit diagram of control inputs (Page 34)).
The controller will be operative after the next switch-on. If a control signal is present, the
door will move in the set direction.
10. Switch on the controller (plug in the mains plug or connector X101).
LED H501 lights red for about two seconds, and then changes to a steady green after the
application software has started and there are no errors in the controller. If the LED
continues to show red, repeat the learn run once more, as described above. If the LED lights
with a red flash code, one of the errors described below is present:
Flash code:
1: CPU error
2: Brake chopper error
3: Error in the second shutdown route
4: Motor temperature monitoring
5: Unknown motor (X801)
6: Blockage detected in closing direction
7: Incremental encoder error (X801)
8: Parameter learn run ended with error
9: Motor overcurrent
10: Blockage detected in opening direction
11: Overvoltage (motor)
12: Undervoltage (motor)
13: Error at the ammeter
14: Determined door weight too high
15: Output stage faulty
16: Overvoltage 15 V circuit
17: Undervoltage 15 V circuit
18: CAN error
Elevator door drive AT12
Equipment Manual, 06/2020, A2B00086683-AD
CAUTION
Electric adjustment and commissioning
17