Connecting A Strobe Device - Omron F160 Setup Manual

Vision sensor
Hide thumbs Also See for F160:
Table of Contents

Advertisement

Connecting a Strobe Device

Cam-
Cam-
Shutter
era
era
speed
F300-
Stan-
SYNC
S3DR
dard
NON
RESET
F300-
Stan-
SYNC
S4R
dard
NON
RESET
Note
1.
2.
3.
5-6

Connecting a Strobe Device

Use the I/O connector's strobe trigger outputs to control the strobe flash tim-
ing. There are two strobe trigger outputs, STGOUT0 and STGOUT1, i.e., one
for each of camera 0 and camera 1.
SeeAlso
Refer to page 31 for details.
Check the strobe device's specifications and set the appropriate "Shutter trig-
ger polarity" and "Shutter trigger width" in the Camera settings (Detail) Menu.
The Camera settings (Detail) window is displayed at startup and can be dis-
played at other times by selecting Camera settings from the System Menu.
64
All manuals and user guides at all-guides.com
Syn-
Strobe
Shutter
chroni-
disable
speed
zation
Start
End
Exter-
-10
-8
1/1,000
nal
-2
0
1/2,000
3
5
1/4,000
5
7
1/10,000
Exter-
-16
-14
1/1,000
nal
-11
-9
1/1,500
-8
-6
1/2,000
-6
-4
1/3,000
-5
-3
1/4,000
-3
-1
1/6,000
-3
-1
1/8,000
-2
0
1/10,000
-2
0
1/30,000
-2
0
1/50,000
The shutter speed is set in the Camera itself, so the shutter speed setting
displayed in the F160 Menu is ignored.
Set the shutter trigger pulse width to match the strobe's specifications only
when a strobe is being used.
These settings (indicated by ---) are ignored.
Clamp pulse
Shutter
1
trigger pulse
Tim-
Width Width Polar-
ing
90
25
7
90
25
7
Section 5-6
Exter-
Image
read Y
nal
timing
VD
3
3
Sync
ity
Nega-
OFF
---
tive
Nega-
OFF
---
tive

Advertisement

Table of Contents
loading