To maintain the F160 in the best condition, perform the following regularly.
Inspection point
Power supply
Ambient tempera-
ture
Ambient humidity
Installation
Indicators
Precaution
44
All manuals and user guides at all-guides.com
• Clean the Lens and LED indicators with a lens-cleaning wipe or blow off
dust with an aerosol air sprayer.
• Lightly wipe off dirt with a soft cloth.
The voltage measured at the power supply
terminals must be 24 VDC
The operating ambient temperature inside
the cabinet must be between 0 and 50 ° C.
The operating ambient humidity inside the
cabinet must be between 35% and 85%.
Each component must be firmly secured.
Each cable connector must be correctly
inserted and locked.
The Cameras must be firmly secured.
The camera lens mounts must be firmly
secured.
All indicators must light when the power is
turned ON.
Verify that a through-image is displayed.
When using an Intelligent Lighting, verify
that the light level settings are set to their
maximum values.
• Turn OFF the power and take safety precautions before conducting
inspections. Electrical shock can result from attempting safety inspections
with the power turned ON.
• Do not use thinners or benzene to clean the F160. They will damage
F160 components.
Details
Circuit tester
+10%
/
.
-15%
Thermometer
Hygrometer
Phillips screwdriver
---
Section 5-3
Tools required