Connecting a Strobe Device
CHECK
The STGOUT0 and STGOUT1 signals will not be output if a Camera is con-
nected only to camera connector 1. When using only one Camera, always
connect it to camera connector 0.
Strobe specifications
STGOUT0 or STGOUT1 signal when the
flash is synchronized to the OFF-to-ON tran-
sition of the strobe trigger signal.
OFF
STGOUT0/1
ON
STGOUT0 or STGOUT1 signal when the
flash is synchronized to the ON-to-OFF tran-
sition of the strobe trigger signal.
W
OFF
STGOUT0/1
ON
Combining an OMRON Camera and Strobe
The following table shows the timing polarity. Use a strobe that is compatible
with this timing.
F150-S1A
F160-S1
F200-S
F300-S
F300-S2R
F300-S3DR
F300-S4R
Note The window used to change the shutter trigger polarity and shutter trigger
pulse will not be displayed when an F150-S1A or F160-S1 Camera is con-
nected, but the STGOUT0 and STGOUT1 signals will be output with the polar-
ity and width shown in the table above.
All manuals and user guides at all-guides.com
Shutter trigger
polarity
Positive
W
Negative
Camera
Shutter trigger polarity
Positive
Positive
Positive
Negative
Shutter trigger width
The "shutter trigger width" setting deter-
mines the pulse width W.
When using a Double-speed Camera:
W = Shutter trigger width setting (H) × 32 µ s
(1H = 32 µ s)
When using a Camera other than a Double-
speed Camera:
W = Shutter trigger width setting (H) × 63 µ s
(1H = 63 µ s)
Note: Depending upon the timing, W may
have an error of up to ± 1H.
Shutter trigger width
3H (1H = 63 µ s)
3H (1H = 32 µ s)
Can be set to match the
strobe's specifications.
3H (1H = 63 µ s)
Section 5-6