MBT High Synchronous Torque Motors
9.7.7

Liquid cooling system

General information
Heat removal device
Machines and systems can require liquid cooling for one or more drive com‐
ponents. If several liquid-cooled drive components exist, they are connected
to the heat removal device via a distribution unit.
he a t re mova l de vice
he a t
output
coola nt line s
he a t
output
coola nt te mpe ra ture
controlle r
Fig. 9-9:
General arrangement of cooling systems with one and more drive
components
The heat removal device dissipates the total heat that was fed into the liquid
into a superordinate coolant. It provides a temperature-controlled coolant and
thus maintains a required temperature level at the components that are to be
cooled.
There are three different types of heat removal devices. They are identified
by the type of the heat exchanger between the different media:
1.
Air-to liquid cooling unit
2.
Liquid-to-liquid cooling unit
3.
Cooling unit
A heat removal device includes a heat exchanger, a coolant pump and a
coolant container (see
fig. 9-10 "Heat removal devices" on page
motor
motor 1
motor 2
motor 3
motor 4
control ca bine t a ir
coole r
control
ca bine t
dis tributor
R911298798_Edition 08 Bosch Rexroth AG
271/409
Application notes
272).