MAD / MAF Asynchronous Housing Motors
8.9

Motor cooling

8.9.1

Fan connection

8.9.2

Coolant connection

The motor fan is connected to the supply network via a cable and a motor
protective switch and is operated independently of the controller.
L1 L2 L3 PE
Power connection cable diameter Ø 7 ... 10 mm
Protective switch
Plug connector
Fan
Fig. 8-11:
Fan connection
To connect the motor fan, the fan connector has to be
opened and closed.
Electric connection may only be established by specialized
staff. Comply with the safety instructions.
The tightness of the connector housing may not be reduced.
Motor protective switch and electric fuse protection are se‐
lected by the machine manufacturer. Please observe the
regulations in the country of installation.
The connector for connecting the motor fan is included in the
scope of delivery and is located on the motor fan.
The following coolant ports can be selected for motors with liquid cooling:
Coolant port via the connection thread on the motor
Coolant port via quick couplings
The inlet (IN) and outlet (OUT) can be arbitrarily assigned. The
assignment does not have any effect on the performance data of
the motor.
Connection techniques
RLS0782
4
0,75 ... 1,5 mm²
3
0,75 ... 1,5 mm²
2
0,75 ... 1,5 mm²
1
RLS0782
R911295781_Edition 11 Bosch Rexroth AG