MBT High Synchronous Torque Motors
8.3.4
Terminal box connection for frame size 360 / 450 / 530
Terminal box example
Connection overview
MST360x-__-FH-_KR-...
Fig. 8-9:
Terminal boxes MST360 / -450 / -530B, -C, -D, -E, -F, -P, -R
A1
A2
A3
MotTemp+
MotTemp-
Ⓐ
Controller
Ⓑ
Terminal box
①
Total shield connection via cable clamp of strain relief in the
cable gland
②
Connect temperature sensor SNM.150.DK to the drive control‐
ler for motor protection
③
Temperature sensor KTY84-130 can be used for external tem‐
perature measurement
Fig. 8-10:
Overview of connections to the terminal box
U
V
W
MST450x-__-FH-_KR-...
MST530B-__-FH-_KR-...
MST530C-__-FH-_KR-...
MST530 -__-FH-_KR-...
D
MST530E-__-FH-_KR-...
MST530 -__-FH-_KR-...
F
MST530 -__-FH-_KR-...
P
MST530 -__-FH-_KR-...
R
1
U (YE)
U
2
V (GN)
V
3
W (BU)
W
PE (GNYE)
1
1
1TP1 (BU)
2
1TP2 (BU)
3
2TP1+ (PK)
4
2TP2- (GY)
5
6
R911298798_Edition 08 Bosch Rexroth AG
253/409
Connection technique
M
3
2
PTC
3
PTC