Maximum Output - Bosch rexroth MBT Manual

High synchronous torque motors
Hide thumbs Also See for rexroth MBT:
Table of Contents

Advertisement

298/409
Motor dimensioning
10.4.3

Maximum output

Bosch Rexroth AG R911298798_Edition 08
P
Continuous power in W
c
P
Mechanical continuous power in W
cm
P
Electrical continuous power loss of motor in W
ce
F
Effective force in N (from application)
eff
v
Average velocity in m/s
avg
F
Rated force of the motor in N (see chapter 4 "Technical data")
dn
P
Rated power loss of the motor in W (see chapter 4 "Technical
vn
data")
Fig. 10-19:
Continuous power of the linear motor
When reducing the continuous torque, the electirc continuous
poweris also reduced
The maximum output is also the sum of the mechanical and electrical maxi‐
mum output. It must be made available to the drive during acceleration and
deceleration phase or for very high machining forces, for example.
P
Total maximum power in W
max
P
Mechanical maximum power in W
maxm
P
Electrical maximum power in W (see the following diagram)
maxe
F
Maximum feed force in N
max
v
Maximum velocity with Fmax in N
Fmax
Fig. 10-20:
Maximum power of the linear motor
When reducing the maximum torque compared to the maximum
torque of the motor, the electric maximum power is also reduced
P
. To determine the reduced electrical maximum output P
maxe
use
Fig.
10-21.
MBT High Synchronous Torque Motors
(seefig.
10-19).
,
maxe