MBT High Synchronous Torque Motors
Stator
MST450B-0012-F... -D303
MST450D-0006-F... -D303
MST450D-0012-F... -D303
MST450E-0006-F... -D303
MST450E-0012-F... -D303
MST530B-0010-F... -NNNN
MST530C-0010-F... -NNNN
MST530C-0010-N... -NNNN
MST530C-0014-F... -NNNN
MST530D-0012-F... -NNNN
MST530E-0010-F... -NNNN
MST530F-0012-F... -NNNN
MST530G-0006-F... -D303
MST530G-0007-F... -D303
MST530G-0010-F... -D303
MST530L-0003-F... -D303
MST530L-0006-F... -D303
MST530L-0007-F... -D303
MST530P-0012-F... -D303
MST530R-0011-F... -D303
MST531E-0006-F...-D303
MST531E-0018-F...-D303
MST531L-0009-F...-D303
Cross section [mm²]
Connection
type
1)
Power
AWG 12
AWG 14
Stranded
wires
AWG 10
AWG 8
REL0109
6.0
(INK0604)
REL0110
10.0
(INK0605)
REL0111
16.0
(INK0606)
2 x 16.0
16.0
Stranded
wires
2 x 16.0
25.0
AWG 8
Stranded
16.0
wires
2 x 16.0
1)
For the amount of stranded wires refer to
2)
Layout according to DIN VDE 0298-4. The required power wire
cross sections apply to laying type B2 (single laying). Laying
type E (multiple installation) and a reduction factor of 0.8 was
taken into account for double cabling.
3)
When using motors with connection mode "stranded wires", the
biggest diameter of the cables (normally of a power wire) is
specified. This allows the minimum bending radius to be deter‐
mined. The diameter of a bundle of the eight stranded wires
(4x power + 4x temperature sensor) can be assumed to be 3
times the specified diameter.
4)
AWG = American Wire Gauge: codes for wire diameters of
electrical lines which are predominately used in North America.
Tab. 8-3:
Connection cables at the stator
Dimension
Ø D [mm]
2)
Sensors
4.0 ±0.2
3.5 ±0.2
see
Tab. 8-2
4.7 ±0.2
6.4 ±0.2
2 x 1.0
18.5 ±1
2 x 1.5
1.0
22.2 ±1
1.5
25.5 ±1
2 x 9 ±0.3
9 ±0.3
see
Tab. 8-2
2 x 9 ±0.3
9 ±0.3
6.4 ±0.2
see
9 ±0.3
Tab. 8-2
2 x 9 ±0.3
R911298798_Edition 08 Bosch Rexroth AG
243/409
Connection technique
Minimum cross
section
"E"
Continuative pow‐
er
[mm]
3)
cable [mm²]
2.5
/
6.0
10.0
4.0
33
6.0
40
10.0
44
16.0
2 x 10.0
2 x 16.0
2 x 25.0
10.0
/
2 x 25.0
25.0
35.0
6.0
/
2 x 10.0
35.0
Fig. 8-3