4 Electrical Installation and Testing

WARNING: Read this Section Carefully Before Installing the System
If all mounting, installation, interfacing, and checkout procedures are not followed properly, the Banner device
cannot provide the protection for which it was designed. The user has the responsibility to ensure that all local,
state, and national laws, rules, codes, or regulations relating to the installation and use of this control system in
any particular application are satisfied. Ensure that all legal requirements have been met and that all technical
installation and maintenance instructions contained in this manual are followed.
The user has the sole responsibility to ensure that this Banner device is installed and interfaced to the guarded
machine by Qualified Persons
The following are the main steps to electrically install the EZ-SCREEN Type 2 components and interface with the guarded machine:
1. Apply power to each emitter/receiver pair (see
2. Perform and Initial Checkout Procedure (see
3. Make all electrical interface connections to the guarded machine (see
29)
4. Perform a commissioning checkout procedure (see

4.1 Routing Cordsets

Connect the QD connectors and route the sensor cables to the junction box, electrical panel, or other enclosure in which the Interface
Module, the redundant mechanically linked interposing relays, FSDs, or other safety-related parts of the control system are located. This
must be done per local wiring code for low-voltage dc control cables and may require installation of electrical conduit. See
page 46 for selection of Banner-supplied cordsets.
The EZ-SCREEN Type 2 is designed and manufactured to be highly resistant to electrical noise and to operate reliably in industrial
settings. However, extreme electrical noise may cause a random Trip or Latch condition; in extreme cases, a Lockout is possible. Emitter
and receiver wiring is low voltage; routing the sensor wires alongside power wires, motor/servo wires, or other high-voltage wiring may
inject noise into the EZ-SCREEN Type 2 System. It is good wiring practice (and may be required by code) to isolate emitter and receiver
cables from high-voltage wires, avoid routing cables close to "noisy" wiring, and provide a good connection to earth ground.
Sensor QD cabling and any interconnect wiring should meet the following specifications. The wires used should have an insulation
temperature rating of at least 90 °C (194 °F).
Table 1: Maximum Machine Interface cable length versus total current draw (including both OSSD loads)
Cable Size
0.823 mm 2 (18 AWG)
0.518 mm 2 (20 AWG)
0.326 mm 2 (22 AWG)*
Note: Cable length includes power (+24 V dc) and return (0 V dc) wires at +25 °C, and is intended to ensure that adequate power
is available to the EZ-SCREEN Type 2 System when the supply is operating at +24 V dc - 10%.

4.2 Initial Electrical Connections

WARNING: Proper Electrical Hookup
Electrical hookup must be made by Qualified Personnel and must comply with NEC (National Electrical Code) and
local standards. Make no more connections to the EZ-SCREEN Type 2 System than are described in this manual.
Connection of other wiring or equipment to the EZ-SCREEN Type 2 System could result in serious bodily injury or
death.
Lockout/tagout procedures may be required (refer to OSHA1910.147, ANSI Z244-1, ISO 14118, or the appropriate standard for
controlling hazardous energy). Following relevant electrical standards and wiring codes, such as the NEC, NFPA79 or IEC60204-1, always
connect the earth ground (green/yellow wire). Do not operate the EZ-SCREEN Type 2 without an earth ground connection.
Make the electrical connections in the order described in this section. Do not remove end-caps; no internal connections are to be made.
All connections are made through the M12 Euro-style quick-disconnects.
3
A person who, by possession of a recognized degree or certificate of professional training, or who, by extensive knowledge, training and experience, has
successfully demonstrated the ability to solve problems relating to the subject matter and work.
3
, in accordance with this manual and applicable safety regulations.
Initial Electrical Connections
Initial Checkout Procedure
Commissioning Checkout
0.5 A
375 ft
240 ft
150 ft
www.bannerengineering.com - Tel: 763.544.3164
on page 23)
on page 25)
Electrical Connections to the Guarded Machine
on page 41)
Current Draw
0.75 A
1.0 A
250 ft
188 ft
160 ft
120 ft
100 ft
75 ft
®
EZ-SCREEN
Type 2 Light Screen
on page
Cordsets
on
1.25 A
148 ft
95 ft
59 ft
23