These are the maximum times from transitioning the input to the drive reacting to the input.
Signal Type and Source
Keypad START
Terminal Strip:
START
STOP , RESET, FL
Preset Speeds
Analog Speed/Trim
Reference
Analog Torque Reference
Network:
START
STOP , RESET, FL
Analog Speed/Trim
Reference
Torque Reference
Downloaded from StockCheck.com
Table A.7 Input Signal Response Times (Worst Case)
Volts/Hertz Regulation
150 milliseconds
126 milliseconds
75 milliseconds
75 milliseconds
16 milliseconds
46 milliseconds + network
26 milliseconds + network
5 milliseconds + network
N/A
25 milliseconds + network
transport time
25 milliseconds + network
transport time
5 milliseconds +
transport time
N/A
0.5 milliseconds + network
Vector Regulation
130 milliseconds
105 milliseconds
75 milliseconds
75 milliseconds
5 milliseconds
0.5 milliseconds
transport time
transport time
network
transport time
transport time
A 3