Terminal
Number
18
Digital Input 7
(Default Ramp1/Ramp2)
Downloaded from StockCheck.com
Table 7.1 Wiring Signal and Control I/O to the Terminal Strip (Continued)
Description
Wiring an Additional Ramp Input
Parameters/Wiring Connections
Digital input 7 is control function programmable through
parameter P .007. The following parameters must be set:
P .000: Control Source
P .001: Accel Time 1 (Ramp 1)
P .002: Decel Time 1 (Ramp 1)
P .006: Second Menu Password
P .007: Terminal Strip Digital Inputs Configure (Selects
and assigns a control function to digital inputs
6 to 8).
P .008 Terminal Strip Speed Reference Source (Analog,
Motor Operated Potentiometer (MOP), or
Preset Speeds)
P .017: Accel Time 2 (Ramp 2)
P .018: Decel Time 2 (Ramp 2)
Note that based on the settings of parameters P .000, P .007,
P .008, and r.030 if an RMI board is used, the following
parameters can affect digital input 7.
P .023: MOP Accel/Decel Time
P .024: MOP Reset Configuration
P .031 to P .038: Preset Speeds 1 8
Refer to the GV3000 Programming instruction manual
(D2 3339) for additional information.
Terminal 18 On = Ramp 2
Diagram shows factory setting.