4310 Wireless Position Monitor
STANDARD LIFE POWER MODULE
EXTENDED LIFE POWER MODULE
Figure 23. Warning Labels from Power Module

Removal

Refer to figure 22.
1. Loosen the two instrument cover screws and
open the cover.
2. Remove the 4 electrical active screws.
22
J1 PWR
TERMINAL
W9645
Figure 24. Power Module
3. Remove the 4 smaller screws providing the
mechanical connection to the housing.
4. Remove both power modules.

Installation

When installing the new power modules, follow the
reverse procedure as outlined above. Recalibrate
the instrument before putting it back into service.
The protective tape covering the J1
PWR and J2 GND terminals of new
power modules must be removed prior
to installation. Refer to figure 22 or 24
for location of terminals.