Perkins SEBU9068-03 Operation And Maintenance Manual page 31

Industrial engine
Table of Contents

Advertisement

SEBU9068-03
2. Fill the tank with DEF that meet all the requirement
defined in ISO 22241-1.
3. Ensure that all DEF lines and electrical connection
are connected prior to prevent crystal from
forming.
4. Ensure that the DEF filler cap is correctly installed.
Removal from Storage
DEF has a limited life, refer to table 2 for the time and
temperature range. DEF that is outside this range
MUST be replaced.
On removal from storage the DEF quality in the tank
must be tested with a refractometer. The DEF in the
tank must meet the requirements defined in ISO
22241-1 and comply with table 2 .
1. If necessary, drain the tank and fill with DEF that
meet ISO 22241-1.
2. Replace the DEF filter, refer to this Operation and
Maintenance Manual, "Diesel Exhaust Fluid Filter-
Clean/Replace".
3. Ensure that the drive belt is correctly installed.
Ensure that all engine coolant and engine oil has
the correct specification and grade. Ensure that
the coolant and the engine oil are at the correct
level. Start the engine. If a fault becomes active
turn off the engine, allow 2 minutes for the DEF
system to purge, then restart the engine.
4. If the fault continues to stay active, refer to
Troubleshooting for more information.
Table 2
Temperature
10° C (50° F)
25° C (77° F)
30° C (86° F)
35° C (95° F)
(1)
(1)
At 35° C, significant degradation can occur. Check every batch
before use.
Duration
36 months
18 months
12 months
6 months
31
Operation Section
Engine and Aftertreatment

Advertisement

Table of Contents
loading

Table of Contents