Perkins SEBU9068-03 Operation And Maintenance Manual page 37

Industrial engine
Table of Contents

Advertisement

SEBU9068-03
SCR System Inducements
Table 5
Warning Indicator
Stop Indicator
OFF
OFF
ON Solid or Slow
OFF
Flashing
(1)
ON Flashing
OFF
Slowly
ON Flashing Fast
ON Solid
(1)
Lamp mode will depend on the issue that has been identified.
SCR System Inducements
Emission Malfunc-
Engine Power
tion Indicator
OFF
Full Power
ON Solid
Start of Engine
Power Derate
ON Flashing
Derate to Engine
Slowly
Power and Speed
ON Flashing Fast
Full Engine Derate
Low Idle (RPM)
Only
Selective Catalytic Reduction Warning System
Time
Comment
-
Normal Operation
Timer Starts, 240
A Level 1 Induce-
Minutes Before Full
ment is Active
Derate
A Level 2 Induce-
ment is Active
A Level 3 Induce-
ment is Active
37
Operation Section
Action
None
Contact your Per-
kins dealer or
your Perkins
distributor.
If a Code has been
Activated Provide
this Information to
Your Dealer.

Advertisement