Function Description - Philio PAT02-A-NS Manual

Flood multisensor
Table of Contents

Advertisement

Function
Description
1. Have Z-Wave
2. Pressing the tamper key three times within 1.5
seconds to enter the inclusion mode.
Add
3. After add successful, the device will wake to
receive the setting command from Z-Wave
Controller about 20 seconds.
1. Have Z-Wave
2. Pressing tamper key three times within 1.5 seconds
Remove
to enter the exclusion mode.
Node ID has been excluded.
Notice: Use this procedure only in the event
that the primary controller is lost or
otherwise inoperable.
1. Pressing tamper key four times within 1.5 seconds
and do not release the tamper key in the 4
pressed, and the LED will light ON.
Reset
2. After 3 seconds the LED will turn OFF, after that
within 2 seconds, release the tamper key. If
successful, the LED will light ON one second.
Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to
factory default.
1. Have Z-Wave
mode.
2. Pressing tamper key three times within 1.5 seconds
to enter the association mode.
Note: PAT02-1A-NS and PAT02-1C-NS are support 2
Association
groups, and PAT02-1B-NS only support 1 group. The
group 1 is for receiving the report message, like
triggered event, temperature, humidity etc. The group
2 is for the light control, the device will send the "Basic
Set" command to this group. And each group support
8 nodes maximum.
Failed or success in add/remove the node ID can be viewed
TM
Controller entered inclusion mode.
TM
Controller entered exclusion mode.
TM
Controller entered association
from Z-Wave
Notice 1: Always RESET a Z-Wave
Z-Wave
TM
network
Notice 2: When the device into NWI mode, the sensor functionality
TM
will useless. The NWI mode will timeout after 30 seconds. You can
press the tamper key 3 times to abort the NWI mode.
Z-Wave
TM
After the device adding to the network, it will wake-up once per day in
default. When it wake-up it will broadcast the "Wake Up Notification"
message to the network, and wake-up 10 seconds for receive the
setting commands.
The wake-up interval minimum setting is 30 minutes, and maximum
setting is 120 hours. And the interval step is 30 minutes.
th
Press the tamper key once. The device will wake-up 10 seconds.
Z-Wave
TM
When the flood triggered the device will report the trigger event and
also report the battery status, temperature and humidity.
In default the device will using Notification Report to represent the
trigger event, it can be changed to Sensor Binary Report by setting the
configuration NO. 7 Bit4 to 1.
* Flood Report: (PAT02-A, PAT02-C)
When the flood triggered, the device will unsolicited to send the report
to the nodes in the group 1.
Notification Report (V4)
Notification Type: Water Alarm (0x05)
Event: Water Leak detected, Unknown Location (0x02)