Philio PAT15 Quick Start Manual

Philio PAT15 Quick Start Manual

Flood water sensor

Advertisement

Quick Links

Flood Water Sensor PAT15
The flood sensor PAT15 has flood, based on Z-Wave
It is the Z-Wave
TM
plus product, it support the security, OTA... Those
newest features of the Z-Wave
communication protocol designed for home automation, specifically to
remotely control applications in residential and light commercial
environments. The technology uses a low-power RF radio embedded or
retrofitted into home electronics devices and systems, such as lighting,
home access control, entertainment systems and household appliances.
This product can be included and operated in any Z-Wave
with other Z-Wave
TM
certified devices from other manufacturers and/or
other applications. All non-battery operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the
network.
TM
technology.
TM
technology. Z-Wave
TM
is a wireless
The device adopt the Z-Wave
network system is all made by Z-Wave
network system will have the advantages as below.
Concurrent multi-channel support reduces external interference.
Better RF range, improve about 10 meters in indoor.
Support 100 Kbps transmit speed, speed up communication.
Specification
Rated
Battery life
RF distance
RF Frequency
RF Maximum Power
Dimension
Location
Operation temperature -20
Humidity
FCC ID
Specifications are subject to change and improvement without notice.
Indication of battery life : Flood Alarm Report:1 times/month, Auto
Report: 4 times/ Day, Auto Wake up 1 time/ Day.
Troubleshooting
TM
network
Symptom
The device can not
join to Z-Wave™
network
1
TM
700 series chip, when your Z-Wave
TM
700 series devices. The
3VDC (CR123A lithium battery)
20 years
Min. 40M indoor,
100M outdoor line of sight,
868.40 MHz, 869.85 MHz(EU)
908.40 MHz, 916.00 MHz(US)
920.9MHz, 921.7MHz, 923.1MHz
(TW/KR/Thai/SG)
+10dBm (Peak), -10dBm (Average)
85(L)x28(W)x23(H)mm
indoor use only
o
C to 50
o
C
85%RH max
RHHPAT15
Cause of Failure
Recommendation
The device may in a Z-
Exclude the device
Wave™ network.
then include again.
TM

Advertisement

Table of Contents
loading

Summary of Contents for Philio PAT15

  • Page 1 +10dBm (Peak), -10dBm (Average) Dimension 85(L)x28(W)x23(H)mm Location indoor use only Operation temperature -20 C to 50 The flood sensor PAT15 has flood, based on Z-Wave technology. Humidity 85%RH max It is the Z-Wave plus product, it support the security, OTA... Those FCC ID...
  • Page 2: Battery Installation

    For Instruction to http:// www.philio-tech.com Replace the new battery and install the cover back. 1. Put the front cover bottom, and press down. Battery Installation 2. Push the front cover top. When the device report the low battery message. The user should replace the battery to new one.
  • Page 3: Function Description

    Add to/Remove from Z-Wave Network CAUTION – replacement of a battery with an incorrect type that can defeat a There are one tamper keys in the back side of the device, It can add, safeguard (for example, in the case of some lithium battery types); remove, reset or association from the Z-Wave network.
  • Page 4 *notice1:The QR code can be found on the device Z-Wave Message Report PAT15 or on the box. This machine provides two groups of nodes. In default the device will using Notification Report to represent the Group 1 can set 1 Nodes.
  • Page 5: Power Up Procedure

    Power Up Procedure And after the flood trigger clear, the device will unsolicited to send the report to the nodes in the group 1. * Battery Power Check When the device power up, the device will detect the power level of the Notification Report (V8) battery immediately.
  • Page 6: Installation

    Installation Z-Wave Configuration Settings 1. To mount the device on the wall, you can choose using the tape, or the screw. Notice: * All of the configuration, the data size is 1. 2. Using the screw to fix the flood detector. *All of the configuration after the remove the setting still keep, don't reset to factory default.
  • Page 7: Z-Wave Supported Command Class

    Security 2 None the product was purchased. They can take this product for Supervision None environmental safe recycling. Philio Technology Corporation None Transport Service 8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City Association Highest granted Security Class 24257, Taiwan(R.O.C) www.philio-tech.com...
  • Page 8: Fcc Interference Statement

    FCC Interference Statement 警語: This equipment has been tested and found to comply with the limits 「取得審驗證明之低功率射頻器材,非經核准,公司、商號或使用者均不得擅自變 for a Class B digital device, pursuant to Part 15 of the FCC Rules. 更頻率、加大功率或變更原設計之特性及功能。 These limits are designed to provide reasonable protection against 低功率射頻器材之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,...

Table of Contents