Philio PAT02-A-NS Manual page 7

Flood multisensor
Table of Contents

Advertisement

Name
NO.
Def.
A B C
Valid
  
0
  
0
  
0
  
0
All
0
  
0
  
0
  
0
  
0
7
Customer
  
0
(*)
Function
  
0
  
0
  
0
  
10 Auto
12
0 ~
Report
127
Battery
Description
Bit4: Reserve.
Bit5: Reserve.
Bit6: Disable the humidity report after
event triggered. (1:Disable, 0:Enable)
Bit7: Reserve.
Customer function switch, using bit
0
0
control.
Bit0: Reserve.
Bit1: Reserve.
Bit2: Reserve.
Bit3: Disable send out BASIC OFF
after the flood event cleared.
(1:Disable, 0:Enable)
Bit4: Notification Type,
0: Using Notification Report.
1: Using Sensor Binary Report.
Bit5: Disable Multi CC in auto report.
(1:Disable, 0:Enable)
Bit6: Disable to report battery state
when the device triggered. (1:Disable,
0:Enable)
Bit7: Reserve.
The interval time for auto report the
battery level.
0 means turn off auto report.
Name
NO.
Def.
Valid
Time
Auto Report
Temperatur
0 ~
13
12
e Time
127
Auto Report
Humidity
0 ~
14
12
Time
127
Auto Report
0 ~
15
12
Flood Time
127
Auto Report
0 ~
20
30
Tick
0xFF
Interval
21
1
0 ~
Temperature
Differential
0x7F
Report
7
Description
A B C
The default value is 12. The tick time
can setting by the configuration No.20.
The interval time for auto report the
temperature.
  
0 means turn off auto report.
The default value is 12. The tick time
can setting by the configuration No.20.
The interval time for auto report the
humidity.
  
0 means turn off auto report.
The default value is 12. The tick time
can setting by the configuration No.20.
The interval time for auto report the
flood state.
  
0 means turn off auto report.
The default value is 12. The tick time
can setting by the configuration No.20.
The interval time for auto report each
tick. Setting this configuration will
effect configuration No.10, No.13,
No.14 and No.15.
  
Units of one minute.
Caution1: Setting to 0 means turn off
all auto report function.
Caution2 : The value is unsigned byte
  
The temperature differential to report.
0 means turn off this function.
The unit is Fahrenheit.
Enable this function the device will
10 seconds
detect every
.