Philio PAT02-A-NS Manual page 3

Flood multisensor
Table of Contents

Advertisement

Sensor Binary Report (V2)
Sensor Type: Water (0x06)
Sensor Value: 0xFF
And after the flood trigger clear, the device will unsolicited to send the
report to the nodes in the group 1.
Notification Report (V4)
Notification Type: Water Alarm (0x05)
Event: 0x00
Sensor Binary Report (V2)
Sensor Type: Water (0x06)
Sensor Value: 0x00
* Tamper Report: (PAT02-A, PAT02-B, PAT02-C)
The tamper key pressed over 5 seconds. The device will into the alarm
state. In that state, if the tamper key be released, the device will
unsolicited to send the report to the nodes in the group 1.
Notification Report (V4)
Notification Type: Home Security (0x07)
Event: Tampering. Product covering removed (0x03)
Sensor Binary Report (V2)
Sensor Type: Tamper (0x08)
Sensor Value: 0xFF
* Temperature Report: (PAT02-A, PAT02-B)
When the flood triggered or the temperature differential over 1
Fahrenheit (in default), the device will unsolicited to send the "Sensor
Multilevel Report" to the nodes in the group 1.
Sensor Type: Temperature (0x01)
Note: To disable send temperature report after the flood triggered,
please setting the configuration N0.5 bit5 to 1.
*** Temperature differential report ***
This function default is enabled, to disable this function by setting the
configuration NO.21 to 0.
In the default, when the temperature is changed to plus or minus one
degree Fahrenheit (0.56 degree Celsius), the device will report
temperature information to the nodes in the group 1.
The device will measure the temperature in every 10 seconds. And if
the temperature is over 140 degree Fahrenheit (60 degree Celsius), the
device will always report in each measurement.
* Humidity Report: (PAT02-A, PAT02-B)
When the flood triggered or the humidity differential over 5 percent (in
default), the device will unsolicited to send the "Sensor Multilevel
Report" to the nodes in the group 1.
Sensor Type: Humidity (0x05)
Note: To disable send humidity report after the flood triggered, please
setting the configuration N0.6 bit6 to 1.
*** Humidity differential report ***
This function default is enabled, to disable this function by setting the
configuration NO.23 to zero.
Enable this functionality, the device will measure the humidity in every
10 seconds. And if the humidity is changed to plus or minus the value
(setting by the configuration NO.23), the device will report humidity
information to the nodes in the group 1.
* Timing Report:
Beside the event triggered could report message, the device also
support the timing unsolicited report of the status.
Battery level report: Every 6 hours report once in default.