Reflective Sensor Heads: FUN M ode Functions
n Offsetting Display Values: One-point Scaling A
Use one-point scaling to offset the display values. Input the distance to be
displayed for the current measurement point. When you input only one
point for scaling, only the offset is changed without changing the range of
display values. In this example, the display values are not inverted.
Example:
Sensor Head
Measured value = Display value
90 mm is displayed as 150 mm.
Display value
(mm)
46
Y
X
Sensing object
80.0
90.0
100.0
110.0
150.0
90.0
90.0
Example: One-point Scaling A
Although the Y value
must be displayed,
the X value is displayed.
If X = 90 mm
and Y = 150 mm,
Display value
Measured value
140.0
80.0
150.0
90.0
160.0
100.0
170.0
110.0
Despite the offset, the range
remains unchanged.
Actual distance (mm)
Section 3-5
: Scaling value input