Calculating Unit - Omron ZX Series Operation Manual

Smart sensors
Hide thumbs Also See for ZX Series:
Table of Contents

Advertisement

Ratings/Specifications
6-1-4

Calculating Unit

Item
Applicable Amplifier Units
Current consumption
Ambient temperature
Ambient humidity
Connection method
Dielectric strength
Insulation resistance
Vibration resistance
(destructive)
Shock resistance
(destructive)
Materials
Weight (packed state)
ZX-LDA11/41
Maximum 12 mA
(supplied from the Smart Sensor Amplifier Unit)
Operating: 0 to 50 ° C, Storage: − 15 to 60 ° C
(with no icing or condensation)
Operating and storage: 35% to 85%
(with no condensation)
Connector
1,000 VAC, 50/60 Hz for 1 min
Ω
100 M
(at 500 VDC)
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y,
and Z directions
2
300 m/s
3 times each in six directions (up/down, left/right,
forward/backward)
Display: Acrylic, Case: ABS resin
Approx. 50 g
Section 6-1
ZX-CAL
155

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zx-gsw11Zx-sw11e v3

Table of Contents