T (Threshold) Mode
n Confirming the Numeric Value
The flashing numeric value must be confirmed to be stored. The numeric
value is confirmed using the following method.
Press the ENT Key.
The display will light continu-
ously after flashing twice.
Changes made to threshold values will be canceled if the mode is
changed using the mode switch or if the setting of the threshold
switch is changed while the display is flashing.
POINT
When you finish adjusting the numeric
value, press the ENT Key to confirm the
value.
All digits will flash twice.
The numeric value will be stored in
EEPROM after the display flashes twice
and then lights continuously.