Operative Instructions; Description Of Manoeuvres; Important Recommendations For Correct Device Installation; Preliminary Information - Cascade UTF2-08-1004-1885315 Use And Maintenance Manual

Table of Contents

Advertisement

5 OPERATIVE INSTRUCTIONS

5.1

Description of manoeuvres

ATTENTION: all lifting operations must
be
performed
authorised personnel only.
5.2

Important recommendations for correct device installation

5.2.1

Preliminary information

In order for the device to function correctly, connections to the truck's hydraulic system must be performed
perfectly. In order to facilitate this task, a list of information that will help correct installation is given below.
It should be pointed out that back pressure in closure, which is shown on the tube opposite that under
pressure, must not exceed 20 bar. Back pressure exceeding this limit will jeopardise device performance. In
the event of malfunctions, the first check to make is that of the back pressure.
Cascade Italia recommends that the following hydraulic capacities and working pressures be
observed in order to optimise device functioning and to avoid problems during operation or start-up.
The values shown below are to be considered a rough guide and can vary from one device to another.
Class of hook
Nominal truck capacity
ISO 2328
1
Up to 999
2
from 1000 to 2500
3
from 2501 to 4999
4
from 5000 to 8000
5
from 8000 to 10999
*) Pressure values valid unless shown otherwise on the device's plate (and EC certificate).
5.2.2

Scaling the hydraulic system

In addition to the pressure and hydraulic capacity
values sent by the truck, correct device functioning
depends on the type of supply system used
between the truck distributor and the device. The
fundamental parameters that influence device
behaviour are the diameter and length of the
tubing, for example, tubes with a diameter that is
too small compared to the relative length and to a
given capacity can cause excessive load losses
that jeopardise the correct functioning of the truck-
device system.
The connection hoses are scaled according to the
capacity actually supplied by the truck to activate
the device and the length of the relative tubing.
19
by
qualified
and
Load's centre
(Kg)
of gravity
400
500
500
600
600
The number shown in brackets refer to the
"Set maps".
Recommended
hydraulic capacity (l/min)
Min
Med
10
15
15
30
20
40
45
60
60
80
The difficulty of creating a perfect hydraulic system
in other words, one that complies with the laws of
hydraulics, is obvious, as it would provide tubing of
an excessive diameter and a very bulky system
that would be very difficult to obtain. The next
paragraph contains a table with the absorption
values for the various tube dimensions, lengths
and hydraulic capacities. This table may help the
operator who prepares the system that links the
truck to the device to install a system that has the
correct dimensions and is optimal for system
functioning, in other words, one that is capable of
obtaining back pressures of approximately 20
bar.
Recommended
working pressure
(BAR)
Max
Max
25
150 *
50
150 *
60
150 *
80
150 *
100
150 *