Programming the NX-535N voice module
Programming the NX-535N via the LED keypad
Entering the program mode
To enter the program mode, press [*]-[8]. At this time, the five functions LED's
(Stay, Chime, Exit, Bypass and Cancel) will begin to flash. Next, enter the "Go To
Program Code" (factory default is [9]-[7]-[1]-[3]). If the "Go To Program Code" is
valid, the "Service" LED will flash and the five function LED's will illuminate
steady. You are now in the program mode and ready to select the module to
program.
Note:
it is impossible to enter program mode if any partition or the system is
armed.
Selecting the module to program
Since all modules connected to the NetworX are programmed through the
keypad, the module you are programming should be the first entry. To program
the NX-535N module, enter [7]-[7]-[#]. The [7]-[7] is the module number of the
NX-535N and the [#] is the entry key.
Programming a location
Once the number of the module to be programmed has been entered, the
"Armed" LED will illuminate, indicating it is waiting for a programming location to
be entered. Any location can be accessed by directly entering the desired
programming location followed by the pound [#] key. If the location entered is a
valid location, the "Armed" LED will extinguish, the "Ready" LED will illuminate,
and the zone LED's will show the binary data for the first segment of this location.
While entering new data, the "Ready" LED will begin flashing to indicate a data
change in process. The flashing will continue until the new data is stored by
pressing the [*] key. Upon pressing the [*] key, the keypad will advance to the
next segment and display its data. This procedure is repeated until the last
segment is reached. Pressing the [#] key will exit from this location and the
"Armed" LED will illuminate again waiting for a new programming location to be
entered. If the desired location is the next sequential location, press the [Police]
key. If the previous location is desired press the [Fire] key. If the same location is
desired press the [Medic] key. To review the data in a location, repeat the above
procedure, pressing the [*] key without any numeric data entry. Each time the [*]
key is pressed, the programming data of the next segment will be displayed for
review.
4
NX-535N Voice Module Installation Manual
Need help?
Do you have a question about the Interlogix NX-535N and is the answer not in the manual?