Siruba ASK-ASM100 Instruction Book / Parts List page 20

Table of Contents

Advertisement

Speed limit of sewing
56
HL
machine head
Motor speed of
57
ACR
assistant trimming
Rotary stitches of
58
ACS
assistant trimming
59
CS
Pedal sensitivity
Needle auto-rising
60
NUF
after power on
Safety switch of side
61
LSH
plate
Highest voltage record
62
HVR
display
Lowest voltage record
63
LVR
display
Present voltage record
64
PV
display
Time setting of auto
65
AOT
running test
66
AO1
Auto running start time
67
AO2
Auto running stop time
68
AOS
Auto Running
Time display of auto
69
UTT
running
70
VER
Software version
Functional automatic
71
GHT
operation
78
PS
Password
The front sensor
79
FED
rotation lock without
fabric
80
BKL
LCD Backlight
81
LAN
Language
Speed controller´s
82
FOO
voltage display
start / stop complex
83
UEG
switch
91
LDL
Motor speed slope
P10
200~5500
3000
rpm
200-5000
3000
rpm
1-99
20
Stitch
1-10
2
level
ON/OFF
ON
//
ON/OFF
OFF
//
//
//
//
//
//
//
Realtime
//
//
display
1~500
240
hr
1~20
2
s
1~20
2
s
ON/OFF
OFF
//
Instantaneous
1~1000
hr
display
ON/OFF
OFF
//
OFF
//
ON/OFF
OFF
//
0%~100%
40%
//
//
English
//
Instantaneous
0~4096
//
display
ON/OFF
ON
165、200、
250、300、
200
ms
350
Speed limit ( first priority). After configure "56.HL"
as 5500rpm, and the parameter "01.H" can be
configured as the highest speed.
Under VTE/CTE mode, after the sewing completes,
press Manual Trimming to activate "trimming and
assistant suction"
IN OT/A mode, set 〝#59.CS〞to decide
the depth of pedaling as to initiate the motor.
The bigger the setting, the deeper you need to pedal.
ON: Enable the needle to rise automatically to the
highest position after power on. OFF: Disable
ON: Enable OFF: Disable
"62HVR" and "63LVR" can record the highest
and the lowest current effective value of the control
box AC.
Set time of auto running test
Set time to start the auto running
Set time to stop the auto running
ON: Enable the auto running test
OFF: Disable the auto running (Resume to OFF after
power off.)
Accumulate running time
The display controller firmware version is SXEX.
If press
key then display UI firmware version
ON
OFF
* Parameters unable to make changes while the
motor is working.
When Password Lock is ON, all parameters cannot be
changed. The unlock password: 0168
Note: To go to the parameter setting, press S and
input the password, hold S till the monitor shows.
Under the OT/A mode, motor stops when the front
sensor detects no fabric.
English / Traditional Chinese / Simplified Chinese
OFF: Only starting function.
ON: Start and stop function.
Motor Acceleration / deceleration slope
165ms, 200ms, 250ms, 300ms, 350ms

Advertisement

Chapters

Table of Contents
loading

Table of Contents