Mounting The Inverter - Generac Power Systems PWRcell XVT076A03 Installation And Owner's Manual

Hide thumbs Also See for PWRcell XVT076A03:
Table of Contents

Advertisement

Installing PWRcell Inverter

Mounting the Inverter

CAUTION
Equipment damage. Mount inverter to a strong, stable surface.
Never mount to drywall, plaster, or other non-structural wall
treatments. Failure to mount inverter to a strong, stable surface
could result in equipment or property damage.
1. Verify mounting location adheres to the following
requirements:
Location
must
requirements listed in Section 3 of this manual.
See
Location
information.
Inverter must be mounted upright on a vertical wall.
Never obstruct intake or exhaust vents.
Never allow water to enter intake or exhaust vents.
Observe all mounting clearances. See
Clearances.
2. Secure
mounting
through mounting holes.
Fasteners must adequately secure the 62.7 lbs
(28.4 kg) inverter weight to the wall.
Fasteners must be suitable for the mounting
surface.
Fasteners must engage at least two studs or other
structural members.
Mounting bracket has clearance holes for 1/4 in
fasteners with slots to accommodate different stud
spacings.
3. See
Figure
4-3. Insert mounting bracket tabs (A)
into inverter body slot (B).
14
(000641a)
meet
all
PWRcell
and
Compliance
for
Mounting
bracket
mounting
NOTE:
Figure 4-3
Inverter
more
Figure 4-3. Mounting Inverter onto Bracket
4. See
Figure
to wall with two fasteners through mounting holes
(C). Holes are spaced at 11 1/4 in. from each other.
Use anchors or blocking as needed.
surface
Installation and Owner's Manual for Generac PWRcell Inverter
is for illustration purposes only.
4-4. Secure the bottom of the inverter
C
Figure 4-4. Mounting Holes
B
A
009991
009992

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pwrcell xvt114g03Pwrcell x7602Pwrcell x11402

Table of Contents