8
Hold the damper vertically. Thread the syringe into the top cap bleed
Hold the damper vertically. Thread the syringe into the top cap bleed
port.
port.
9
Inject the oil into the damper assembly.
Inject the oil into the damper assembly.
Push the assembly down to compress the rebound shaft. The syringe
Push the assembly down to compress the rebound shaft. The syringe
will fill up.
will fill up.
Depress the syringe to inject oil into the damper assembly and allow
Depress the syringe to inject oil into the damper assembly and allow
the rebound shaft to fully extend.
the rebound shaft to fully extend.
Repeat cycling the fluid 3-4 times.
Repeat cycling the fluid 3-4 times.
10
Push the syringe handle down, then release the plunger. Allow the
Push the syringe handle down, then release the plunger. Allow the
bladder to come to a natural resting position by waiting a few moments
bladder to come to a natural resting position by waiting a few moments
until the syringe stops filling.
until the syringe stops filling.
Use a shop towel to cover the bleed tip and bleed port, then unthread
Use a shop towel to cover the bleed tip and bleed port, then unthread
and remove the syringe.
and remove the syringe.
Make sure the rebound shaft is fully extended and there is a small
Make sure the rebound shaft is fully extended and there is a small
amount of positive pressure in the system before the syringe is
amount of positive pressure in the system before the syringe is
removed. This prevents air getting back into the damper.
removed. This prevents air getting back into the damper.
⚠ CAUTI ON - EYE HAZARD
Oil will eject from the bladder assembly if the bladder is not in its
resting position. Wear safety glasses.