TROUBLESHOOTING

RUNNING THE SOFTWARE WITHOUT AN EVAL-
ADIS2 EVALUATION BOARD ATTACHED
The user will see the following screens if the evaluation software
is run without the EVAL-ADIS2 connected:
In this case, the user should exit out of the software, and
proceed to the "EVAL-ADIS2 Physical Connections" section of
this user guide and ensure that the evaluation board is properly
connected and powered prior to running the evaluation
software.

DEVICE BLACKLISTED

The most common cause of this error is attempting to read the
registers of the IMU while the EVAL-ADIS2 evaluation board is
disconnected from the PC after having previously been
successfully connected. Communication can be restored by
reconnecting the EVAL-ADIS2 to the PC.

LOG FILE ERROR

This error occurs if the filename specified for the data log file
already exists. The user should either rename the existing file or
choose a different filename for the new log file.