4. SYSTEM MENU
4.11

How to Setup the Tanks

The FI-70 can show information for up to six tanks. The tanks must be connected to
the same network as the FI-70.
If your tank has a single sensor installed, tank data is automatically supplied to the FI-
70 and the following procedure is not required. If your tank has more than one sensor,
or is connected via a interface, such as an IF-NMEAFI, set the tank details with the
following procedure.
Note: This menu appears in gray when the connected tanks are not available for set-
up. If this occurs, check the connections between the FI-70 and the tank and check
the tank's sensor status. If the problem cannot be resolved, contact your local dealer.
1. Access the [System] menu using the procedure outlined on page 4-1.
2. Press the software keys to select [Tank Source], then press the function key.
3. Press the software keys to select [Source], then press the function key.
4. Press the software keys to select the CAN ID for the tank you want to setup, then
press the function key.
5. Press the software keys to select [Instance], then press the function key.
6. Press the software keys to select the tank instance, then press the function key.
7. Press the software keys to select [Fluid Type], then press the function key.
8. Press the software keys to select the type of fluid stored in the tank, then press
the function key.
9. Press the Menu/Back key twice to close the menu.
4-14
Tank Source
Fluid Type:
Source:
Instance:
Ent
----------------
----------------
----------------
----------------