Furuno FI70BW User Handbook Manual

Furuno FI70BW User Handbook Manual

Color instrument
Hide thumbs Also See for FI70BW:

Advertisement

Quick Links

COLOR INSTRUMENT
This User Handbook covers the basic installation and operation of the FI-70.
For detailed information, refer to the Operator's Manual, not included with the product
carton but accessible from the URL or quick response code to the right.
URL: http://www.furuno.com/en/support/manuals/terms
In the search box at the top of the screen, enter "FI-70", then click "Search".
SAFETY INSTRUCTIONS............................................................................................................ 1
UNIT OVERVIEW, FUNCTIONS .................................................................................................. 2
INSTALLATION ............................................................................................................................ 2
Flushmount Installation ........................................................................................................ 2
Frontmount Installation (Option)........................................................................................... 3
WIRING ........................................................................................................................................ 4
Network Connection ............................................................................................................. 4
Grounding ............................................................................................................................ 4
INITIAL SETTINGS....................................................................................................................... 5
How to Select a Language and Units of Measurement ........................................................ 5
How to Set Up Own Ship Type ............................................................................................ 5
How to Select the Data Source ............................................................................................ 6
How to Set Up the IF-NMEAFI (option) ................................................................................ 6
STANDARD OPERATION............................................................................................................ 7
How to Adjust Brilliance and Change Between Day/Night Modes ....................................... 7
How to Change Pages ......................................................................................................... 7
How to Adjust Page Settings (Displayed Category) ............................................................. 7
Page List by Category.......................................................................................................... 8
HOW TO EDIT THE CUSTOM BOXES........................................................................................ 9
How to Adjust Data Box Displayed Data .............................................................................. 9
How to Adjust Data Box Size Settings ............................................................................... 10
SHARING AND GROUPS .......................................................................................................... 11
Network Settings ................................................................................................................ 11
Language and Brilliance Sharing Between FI-70 Units...................................................... 11
MENU TREE............................................................................................................................... 12
Main Menu ......................................................................................................................... 12
Category Specific Menus ................................................................................................... 14
OUTLINE DRAWINGS .........................................................................................................D-1
INTERCONNECTION DIAGRAM........................................................................................ S-1
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.
USER HANDBOOK

TABLE OF CONTENTS

www.furuno.com
FI-70
Model

Advertisement

Table of Contents
loading

Summary of Contents for Furuno FI70BW

  • Page 1: Table Of Contents

    For detailed information, refer to the Operator’s Manual, not included with the product carton but accessible from the URL or quick response code to the right. URL: http://www.furuno.com/en/support/manuals/terms In the search box at the top of the screen, enter “FI-70”, then click “Search”.
  • Page 2: Safety Instructions

    SAFETY INSTRUCTIONS The operator and installer must read the applicable safety instructions before attempting to operate or install the equipment. Indicates a potentially hazardous situation which, if not avoided, could WARNING result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, can CAUTION result in minor or moderate injury.
  • Page 3: Unit Overview, Functions

    UNIT OVERVIEW, FUNCTIONS 3. Software keys Software keys Change displayed page Move cursor Adjust settings 4. Function key Function Confirm selection/changes Switch displayed data 5. Key Indicators Key Indicators The indicators show the operative function for the Software and Function keys. Press any key to display the indicators.
  • Page 4: Frontmount Installation (Option)

    Frontmount Installation (Option) The optional frontmount kit OP26-29 may be used to install the FI-70 where access behind the console is limited. Note: Do not fit the flushmount sponge to the FI-70. The unit will not lock into the frontmount panel. Using the template supplied with the frontmount kit, cut a hole in the mounting location.
  • Page 5: Wiring

    WIRING Analog sensors Wind Transducer FI-5001/L Speed/Temp. Sensor Tank gauge ST-02MSB/ST-02PSB Analog NMEA Data Converter Color Instrument FI-70 (Maximum 11 units) IF-NMEAFI CAN bus (NMEA2000) CAN bus sensors 12 VDC (NMEA2000) sensors 15 VDC Junction Box Junction Box FI-5002 FI-5002 CAN bus (NMEA2000) Backbone: Terminal resistors must be installed at both ends of the backbone.
  • Page 6: Initial Settings

    INITIAL SETTINGS After mounting and wiring are completed, when the CAN bus (NMEA2000) network is turned on, the FI-70 will start up. If this is the first time the FI-70 has been powered, the [Initialization] menu is displayed. Set the language, units of measurement and your ship type in this menu.
  • Page 7: How To Select The Data Source

    How to Select the Data Source How to Select the Data Source This section explains how to set the data source(s) for displayed data. Select [System] from the main Select [Data Source], then Select the item who’s data source menu, then press the function press the function key.
  • Page 8: Standard Operation

    STANDARD OPERATION How to Adjust Brilliance and Change between Day/Night Modes How to Adjust Brilliance and Change between Day/Night Modes Screen brilliance and changing from Day to Night mode may be done from the Brilliance setting window. The Brilliance setting window disappears if the Menu/Back is pressed, or if there is no interaction over a short period. Press the Power/Brill key to display Press the software keys to Press the function key to change...
  • Page 9: Page List By Category

    Page List by Category Page List by Category On-screen data display may be changed by pressing the function key. Note1: On-screen data display requires connection of the appropriate sensor and [Data Source] menu set up. Note2: All maximum and average data are cleared at power off and calculated from power on. Compass Compass Speed...
  • Page 10: How To Edit The Custom Boxes

    Timer Timer Countdown Timer1 Countdown Timer1 Countdown Timer1 Countdown Timer1 Countdown Timer1 Countdown Timer2 Countdown Timer2 Countup Timer Countup Timer Time Time Time 00:00 15:00 15:00 00:00 00:00 00:00 Trip Trip Countdown Timer Lap Time Trip Meter Countup Timer Highway Highway Custom Box Custom Box...
  • Page 11: How To Adjust Data Box Size Settings

    How to Adjust Custom Box Size Settings How to Adjust Custom Box Size Settings With the Custom Data box page Select the box to adjust, then Select [Select Box Size], displayed, press the function key. press the function key. then press function key. Depth W Temp.
  • Page 12: Sharing And Groups

    SHARING AND GROUPS Network Settings Network Settings Some settings and offsets for the FI-70 may be shared across a CAN bus (NMEA2000) network. See the list below for details. Select [System] from Select [Sharing], then Select the sharing level press the function for this FI-70 unit, then the main menu, then press the function key.
  • Page 13: Menu Tree

    MENU TREE Main Menu Default settings shown in bold italic. Menu/Back key Menu/Back key Displayed page-based menus (See Pages 14 to 15) Alarms STW Alarm Alarm (OFF, Low, High; 0.0kn to 999.9kn, 10.0kn) Buzzer (Short, Middle, Long, Continue) SOG Alarm Alarm (OFF, Low, High;...
  • Page 14 (Continued from previous page) Engine Setup Number of Engine (1 to 3, 1) Engine Assign (1 to 4, 1) Where [Number of Engine] is set to [1] Engine PORT (1 to 4, 1) Where [Number of Engine] is set to [2] or [3] Engine STBD (1 to 4, 2) Where [Number of Engine] is set to [2] or [3] Engine Center (1 to 4, 3) Where [Number of Engine] is set to [3] Engine Refresh...
  • Page 15: Category Specific Menus

    (Continued from previous page) Tank Source Tank1 Fluid Type (Fuel, Fresh Water, Waste Water, Tank2 (Same as Tank1) Live Well, Oil, Black Water, Tank3 (Same as Tank1) Fuel (Gasoline)) Tank4 (Same as Tank1) Source (Select from displayed list) Tank5 (Same as Tank1) Instance (0 to 14) Tank6 (Same as Tank1) Data Calibration...
  • Page 16 AWA, TWA, CH AWA, CH TWA, Ground Wind AWA, TWA, CH AWA, CH TWA, Ground Wind AWA, TWA, CH AWA, CH TWA, Ground Wind AWA, TWA, CH AWA, CH TWA, Ground Wind AWA, TWA, CH AWA, CH TWA, Ground Wind Press the Menu/Back key Wind Speed Wind Damping (0 to 12s, 3s)
  • Page 20 Pub. No. E72-01403-F (2004, REFU) FI-70 00019006615...

This manual is also suitable for:

Fi-70Fi70dsw

Table of Contents