5. INSTALLATION AND INITIAL SETTINGS
5.1.1

Flushmount

Using the figure below for reference, follow the procedure to flush mount the FI-70.
Note: When retrofitting from a FI-50 series instrument, re-drill the stud bolt holes
where the FI-50 series instrument was installed to allow use of the mounting hole.
1. Using the supplied template, cut a hole in the mounting location.
2. Fit the stud bolts (M3×40, 2 pcs, supplied) to the rear of the FI-70.
Note: Do not use tools to fit or insert the stud bolts.
3. Fit the flushmount sponge (supplied) to the rear of the FI-70.
4. Feed the cable through the cutout, then fit the cable to the FI-70.
5. Set the FI-70 into the mounting hole, making sure the FI-70 is oriented upwards.
6. Fit and tighten the washers and butterfly nut (washers and butterfly nut supplied).
When using locally supplied materials
When using locally supplied screws to secure the FI-70, the thread depth should be
approx. 5 mm, as indicated in the figure below.