Safety Instructions Safety Instructions • English Инструкция по технике безопасности • Русский WARNING: This symbol, , when used on the product, is intended ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан to alert the user of the presence of uninsulated dangerous voltage на...
Page 4
Conventions Used in this Guide Notifications In this user guide, the following are used: Potential risk of severe injury or death. WARNING: AVERTISSEMENT : Risque potentiel de blessure grave ou de mort. CAUTION: Risk of minor personal injury. ATTENTION : Risque de blessure mineure.
Contents Introduction Mounting ............1 ............... 24 About the TLP Pro 720 and Mounting the TLP Pro 720M and TLP Pro 1020 Series ..........1 TLP Pro 1020M ...........24 Features ..............1 Rack Mounting ..........24 Application Diagram ..........3 Wall Mounting the TLP Pro 720M and TLP Pro 1020M ..........24 Furniture Mounting the TLP Pro 720M and Installation Overview...
Introduction This guide describes the function, installation, and operation of the following Extron TLP Pro 720 Series and TLP Pro 1020 Series of Touchlink Pro Touchpanels: TLP Pro 720M TLP Pro 720T TLP Pro 1020M TLP Pro 1020T Unless otherwise stated, the term TLP Pro refers to all four models. The terms TLP Pro 720 or TLP Pro 720 Series refer to the TLP Pro 720M and TLP Pro 720T models.
Page 8
Built-in speakers — one speaker (TLP Pro 720 Series) or two (TLP Pro 1020 Series), with improved audio performance provide audible feedback from button presses. Light sensor — adjusts screen brightness as the ambient room lighting changes. Configurable red and green status lights — indicate the availability or call status of a room. System connection status indicator —...
Application Diagram The application diagram below shows the TLP Pro 720M. The other touchpanels in this user guide can be used in similar configurations. Extron COM 1 COM 2 DIGITAL I/O IPCP PRO 250 IPCP Pro 250 Tx Rx RTS CTS Tx Rx Laptop Tuner...
Installation Overview Before starting, download and install the latest versions of the following software: Global Configurator Plus and Global Configurator Professional — for setting up and configuring the control processor and touchpanel. GUI Designer — for designing layouts for Extron TouchLink Pro touchpanels and third ...
Panel Features This section describes: TLP Pro 720 Series and TLP Pro 1020 Series Front Panel Features TLP Pro 720M and TLP Pro 1020M Front Panel with Bezel Removed TLP Pro 720 Series and TLP Pro 1020 Series Rear Panel Features TLP Pro 720 Series and TLP Pro 1020 Series Front Panel Features Extron TLP Pro 720M...
Page 12
Status lights — one on each side can be programmed to provide system feedback. Light red or green Blink or light continuously Motion sensor — detects motion between three to five feet from the touchpanel, and at least 15° from the center axis. When no motion has been detected for a user-defined period of time, the touchpanel enters sleep mode.
TLP Pro 720M and TLP Pro 1020M Front Panel with Bezel Removed Remove the front bezel by inserting the Extron removal tool into the slots on the bottom of the unit and separating the bezel from the touchpanel. The following additional features are concealed behind the bezel: C C D D C C D D...
TLP Pro 720 Series and TLP Pro 1020 Series Rear Panel Features Extron TLP Pro 720T TLP Pro 1020T N15779 I.T.E. N15779 1T23 I.T.E. 1T23 33-2455-01 A POWER Patent(s) www.extron.com/patents 33-2453-01 A 12 V POWER Patent(s) www.extron.com/patents 1.0 A MAX LAN / PoE 12 V 1.0 A MAX...
Page 15
Power connector (see figure 5, on the previous page)— power supplies must be purchased separately. TLP Pro 720T and TLP Pro 1020T — Connect a 12 VDC, 1.0 A power supply with DC plug to the rear panel power receptacle. Extron recommends using the PS 1210 P power supply (part number 70-778-01).
Page 16
ATTENTION: Always use a power supply provided by or specified by Extron. Use of an • unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the end product. Utilisez toujours une source d’alimentation fournie ou recommandée par Extron. •...
Page 17
Network and Power Injector Connector (see figure 5)— is on the right side of the recessed area. Connect the touchpanel to the LAN using a twisted pair cable, terminated with an RJ-45 connector. Use a straight-through Ethernet cable to connect the panel to a switch or router. Use a crossover cable to connect the panel directly to a computer.
Page 18
ATTENTION: The touchpanels are intended for connection to a Power over Ethernet circuit for • intra-building use only and are considered to be part of a Network Environment 0 per IEC TR62101. Les écrans tactiles sont conçu pour une connexion à un circuit PoE pour une •...
Page 19
Menu button (see figure 5)— activates the setup menu (see the following page) and Calibration screen (see page 19). Reset button (see figure 5)— initiates one of three reset modes for the unit (see Reset Modes on page 30). Reset LED (see figure 5)—...
On-screen Menus On-screen menus allow initial configuration of the TLP Pro 720 series and TLP Pro 1020 series: Setup Menu Calibration Screen Setup Menu To open the setup menu, press the button. For the TLP Pro 720T and TLP Pro 1020T, the Menu figure Menu button is located on the rear panel (see...
Network Screen Verify with your network administrator whether the IP address for the touchpanel is assigned by Dynamic Host Configuration Protocol (DHCP) or set manually. If they are set manually, you need to obtain an IP address, a subnet mask, a gateway address, and a Domain Name Server (DNS) IP address from the network administrator.
Page 22
If DHCP is disabled, set the unit IP address, subnet mask, gateway address, and DNS server address. Press the button for the address to be edited. A screen opens, showing the address and a numerical keypad. IP Address Clear 1 9 2 1 6 8 2 5 4 2 5 1...
Display Screen Display Audio Advanced Exit Status Network Auto Brightness Sleep Timer LCD Brightness Minutes Wake on Motion Figure 12. Display Screen The Display screen allows you to set the Sleep Timer, Auto Brightness, LCD Brightness, and Wake on Motion. The Sleep Timer determines how long the panel will be inactive before it enters sleep mode, when the screen goes dark to save power —...
Calibration Screen Touch crosshair to calibrate 800 x 480 Figure 16. Calibration Screen Press and hold down the Menu button for at least 3 seconds. For the TLP Pro 720T and TLP Pro 1020T, the Menu button is located on the rear panel (see figure on page 8).
Configuration Software This section of the user guide provides information about: Configuration Software TLP Pro 720 Series and TLP Pro 1020 Series Web Pages Updating the Firmware Configuration Software Designing a graphical user interface (GUI) for the TouchLink Pro touchpanel takes two steps: Design the layout of the screen text and graphics using GUI Designer.
(see page 14) or the Toolbelt feature of Global Configurator to configure the touchpanel network settings. Figure 17 shows the TLP Pro 1020T web page. The web page for the other touchpanels is similar. Extron Electronics ® General Status Project...
Updating the Firmware Firmware for both touchpanels can be upgraded using the Toolbelt feature of Global Configurator or the touchpanel web page. Before starting, consult your IT team and ensure that the touchpanel has a unique IP address. Downloading Firmware Power on a computer that is connected to the same network as the touchpanel. On the Extron website, click Download in the menu bar along the top of the page (see figure 18, ...
Mounting This section outlines the various options for: Mounting the TLP Pro 720M and TLP Pro 1020M Rack Mounting Wall Mounting the TLP PRO 720M and TLP Pro 1020M Furniture Mounting the TLP PRO 720M and TLP Pro 1020M Mounting the TLP Pro 720T and TLP Pro 1020T Desktop Mounting VESA Mounting Mounting the TLP Pro 720M and TLP Pro 1020M...
Page 30
TLP Pro 1020M: BB 1000 or EWB 1000 kits Follow the instructions provided with the kit. Without a Wall Box The touchpanels can also be mounted directly into drywall, without a kit. ATTENTION: Do not install the TLP Pro 720M or the TLP Pro 1020M in a fire resistant rated wall or •...
Ensure the locking arms are flush with top and bottom of the touchpanel and fit the touchpanel into the hole. TLP Pro 720M — four locking arms, two at the top and two at the bottom. TLP Pro 1020M — five locking arms, two at the top and three at the bottom. Use a Phillips head screwdriver to tighten the locking arm screws.
Push excess cable into the lectern. Ensure the locking arms are flush with top and bottom of the touchpanel and fit the touchpanel into the hole. The TLP Pro 720M has four locking arms, two at the top and two at the bottom. The TLP Pro 1020M has five locking arms, two at the top and three at the bottom.
Page 33
Placement with a Kensington Security Lock Kensington Security Slot Figure 23. TLP Pro 720T Base, Showing Kensington Security Slot For added security, attach a Kensington Security Lock (not provided) to the metal-reinforced slot on the rear edge of the base. Figure 23 shows the rear edge of the TLP Pro 720T base, but the TLP Pro 1020T base is very similar.
Locking Plate Locking Screw Figure 25. Locking Plate and Locking Screw Remove the screw holding the locking plate at the bottom of the base. This releases the weight, which can be removed from the top of the base, leaving the mounting hole that will fit over the conduit of the SMA-1.
Page 35
VESA mounting the TLP Pro 720T and TLP Pro 1020T If necessary, connect the cables and use a zip tie to secure them to the back of the touchpanel. Secure a VESA D 75 mm mount kit to the back of the touchpanel Follow the instructions provided with the mounting kit.
Reference Material This section describes: Reset Modes Licensed Third-Party Software Used in the Touchpanels Reset Modes The TLP Pro 720 Series and TLP Pro 1020 Series touchpanels have three reset modes that are initiated by pressing the Reset button: Use Factory Firmware Reset All IP Settings Reset to Factory Defaults The Reset button on the TLP Pro 720M or TLP Pro 1020M, is found on the front panel after...
Purpose and Notes Use this mode to temporarily boot up the unit with factory installed firmware for a single power cycle in the event that a firmware update has failed or if incompatibility issues arise with user- loaded firmware. NOTE: User-defined web pages may not work correctly if you are using an earlier firmware version.
Licensed Third-Party Software Used in the Touchpanels The touchpanels use various licensed third-party software packages during operation. To view details about third-party packages and associated licensing, click the License Information internal Web page button on the Unit Information page of the (see page 21).
Page 39
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.