Configuration Digit
Setting
10
(LOAD)
11
(GROUND ALARM)
12
(ENGINE SHUTDOWN)
Model
33RT 2WD,
33RT 4WD
33RT 2WD
33RT 4WD
NOTE: Vehicle Tilt Configuration based on Model and Market Settings
3121133
Table 5-3. Machine Configuration Programming Information
0
NOT INSTALLED – Load Sensing System (LSS) is not fitted to the vehicle.
1
CUTOUT PLT – Load Sensing System (LSS) is fitted, and Platform Controls are pre-
vented in the event of an Overload. Ground Controls remain functional. This is the default
2
CUTOUT ALL – Load Sensing System (LSS) is fitted. Platform and Ground Controls are
NOTE: Certain market selections will alter default setting.
0
NOT INSTALLED – Vehicle alarm will function for Overload (if LOAD enabled).
1
DESCENT – Vehicle alarm will function for Overload (if LOAD enabled) and during Lift
2
MOTION – Vehicle alarm will function for Overload (if LOAD enabled), during Drive
NOTE: Certain market selections will alter default setting.
0
NO - The engine will not be automatically shutdown.
1
SHUTDOWN - The engine will automatically shutdown in the event of high engine coolant
temperature, low oil pressure, or a temperature sensor or oil pressure sensor fault.
Table 5-4. Machine Tilt Configuration
Market
Lift Up and Drive prevented when Elevated and Tilted beyond the following limits:
ANSI USA
Front to Back: ±5° to Full Height
Side to Side: ±5° to 26 Feet; ±4° to 30 Feet; ±3° to Full Height
ANSI EXPORT
Same as ANSI USA
Lift Up and Drive prevented when Elevated and Tilted beyond the following limits:
CSA
Front to Back: ±3° to Full Height
Side to Side: ±3° to Full Height
Tilt Lamp energized when Tilted beyond the following limits:
CE
Front to Back: ±5° to Full Height
Side to Side: ±3° to Full Height
AUSTRALIA
Same as ANSI USA
Lift Up and Drive prevented when Elevated and Tilted beyond the following limits:
ANSI USA
Front to Back: ±5° to Full Height
Side to Side: ±5° to 30 Feet; ±4° to 36 Feet; ±3° to Full Height
ANSI EXPORT
Same as ANSI USA
Lift Up and Drive prevented when Elevated and Tilted beyond the following limits:
CSA
Front to Back: ±3° to Full Height
Side to Side: ±3° to Full Height
Tilt Lamp energized when Tilted beyond the following limits:
CE
Front to Back: ±5° to Full Height
Side to Side: ±3° to Full Height
AUSTRALIA
Same as ANSI USA
SECTION 5 - JLG CONTROL SYSTEM
Description
setting for CE machines.
prevented in the event of an Overload.
Down motion.
motion, and during Lift motion.
LImits
– JLG Lift –
Default Number
0
2
1
4150390 J
4150390 J
5-19