INSTALLATION (continued) 
3. Flange (LVU809 series):  If installing on a flange, select a flange with a thread that is above the plane of 
the flange.   
a. The LVU816, LVU826 & LVU832 series works well with Flange installations. 
b. Avoid the use of blind flanges with tapped threads or flanges where the threads are even with 
the plane of the flange, such as the Banjo 1" Poly ANSI Flange (series AF100).  
c. Use a flange with a 2" thread and add a 2" to 1" reducer bushing to complete the installation. 
2" Flange w/ 
thread out of plane 
(LVU800‐2F shown) 
 
4. Side  Mount  Bracket:    For  installations  in  open  tanks  and  sumps,  use  the  LVM‐30  or  
LVM‐31 series side mount bracket.   
a. For the LVU809 series, order the LVM‐31 side mount bracket.   
b. For the LVU816, LVU826 & LVU832, series, order the LVM‐30 side mount bracket. 
 
 
2" Flange w/
thread in plane 
 
Do not use thread in plane 
 
(LVU800‐2N80 shown) 
 
18 
2" Flange w/ 
Reducer Bushing 
Step Six 
 