GETTING STARTED (continued)
DISPLAY ‐ AIR Mode vs. LIQUID Mode:
The display can be made to display either the height of liquid in the
tank (LIQUID mode) or the amount of air in the tank (AIR mode).
AIR mode – Will display the distance from the bottom of the sensor to
the surface of the liquid.
LIQUID mode – Will display the height of liquid measured from the
bottom of the tank.
How to change the display mode:
1. In the MENU mode, press select when UNITS is display.
2. Press SELECT when DISPLAY appears.
3. Press SELECT to choose between AIR or LIQUID.
4. When EXIT appears, press SELECT return to Top Level Menu.
10