ECO10LCDJR COMBINATION THERMOSTAT
ECO10LCDJR electronic combination thermostat is mounted as the cover of a 1-component
mounting box or as a part of a multiple-component instrument panel. The thermostat is suit-
able for use with Jussi range of accessories.

1. SAFETY INSTRUCTIONS

Installation must only be carried out by an electrician with the appropriate qualifications.
Read the installation instructions carefully before starting the installation work.
The instruction manual must be stored in a safe location and be available for future instal-
lation and service.
2.
CONNECTION
See the wiring diagram on page 18.
Disconnect the power supply before carrying out any installation or maintenance work
on this thermostat and associated components.
2.1. A residual current switch according to local regulations must be used in installations.
3.

BEFORE INSTALLATION

3.1. Check that all the parts and tools needed for the installation are available. This package
contains a thermostat, a cover, a frame, an additional connector for earth wires (PE), a sensor
cable and this installation instructions booklet.
3.2. Check that the heating load is equivalent to the thermostat power rating.
3.3. Check the insulation resistance and the circuit resistance of the heating load controlled by
the thermostat. For more information, please see the heating load instructions.
4.
INSTALLATION
4.1. Place the sensor cable in a dry protective tube between heating cables (floor heating solu-
tions). NOTE! Make sure that there is not water in the protective tube.
4.2. Connect the earthing wires (PE) to the separate connector.
4.3 Connect the thermostat according to the wiring diagrams. The thermostat has screw ter-
minals, strip the leads at the length of 7 mm.
4.4 Mount the thermostat into the mounting box with screws.
4.5. Mount the frame and cover according to figure.
Warning! Do not apply pressure to the corners of the display or to the display itself.
4.6. Start the thermostat by pressing main switch button