Introduction; Safety Instructions; Included In The Package; Operation Modes - ensto ECO920 Installation And Operation Instructions Manual

Table of Contents

Advertisement

Installation instructions

1. Introduction

ECO920 is a microprosessor controlled thermostat equipped with a LCD display.

2. Safety Instructions

Installation must only be carried out by an electrically skilled person.
Read the installation instructions carefully before starting the installation work.
The information provided in this manual in no way exempts the user of responsibility to follow all ap-
plicable codes and safety standards.
The instruction manual must be stored in a safe location and be available for future installation and
service.

3. Included in the package

ECO920 thermostat
ECOA909 temperature sensor
Installation and operating instructions

4. Operation modes

The thermostat has four operation modes. The operation mode can only be installed in the START UP
menu, which is shown the first time the thermostat is started or after the thermostat has been reset to
factory settings.

4.1 Heating

HEAT mode is used in homes, offices, storerooms and suchlike. You can use the thermostat as a room or
floor thermostat or as a room thermostat with over heating protection for wooden floors. You can regulate
the heating within a temperature range of +5 ... +45 ºC.

4.2 Cooling

COOL mode is used in homes, offices, storerooms and suchlike. The thermostat works as a room thermo-
stat for regulating air conditioning or other cooling within a temperature range of +5 ... +45 ºC.

4.3 Industry

INDUSTRY mode is used in industrial environment to regulate the temperature of industrial processes, high
temperatures or for frost protection of sensitive installations. You can regulate temperatures within the
ranges -15 ... +75 ºC and 0 ... +170 ºC. You can limit the temperature range to -10 ... +15 ºC for frost protec-
tion purposes. You can adjust temperature hysteresis as well as set upper and lower temperature alarms.

4.4 Frost Protection

MAX/MIN mode is used to keep roof and ground surfaces free of snow and ice. You can adjust the frost
protection within a temperature range of -20 ... +10 ºC.

5. Installation and electrical connections

Disconnect the power supply before carrying out any installation or maintenance work on this ther-
mostat and associated components.
The thermostat is intended for mounting in a panel board. Attach the device onto a DIN rail.
The thermostat do not have a main switch in itself, but it has to be installed elsewhere in the circuit.
A residual circuit breaker has to be used according to the local installation regulations.
Sensors in accordance with the used application should be installed to ensure proper operation and
energy saving.