Appliance Set-Up

A. Leveling System
The leveling bolts are located at the rear of the appliance.
To access the bolts, remove the side access panels.
Reach in and turn the bolt to the desired height to level the
appliance (Figures 21.1 and 21.2).
Leveling Bolt on each Side
Figure 21.1
2 inch diameter Flex Pipe
Figure 21.2
B. Door Handle Removal
1. Open the door.
2. Using a 5/32 Allen wrench, loosen set screw by a
couple of turns, but do not remove.
3. Push the pin completely out and remove the handle.
4. Re-install in reverse order.
C. Door Removal
1. Remove the door handle and face.
2. The door can now be lifted off the hinges.
3. Re-install in reverse order.
21
D. Outside Air Kit Instructions
1. Measure distance from floor to air vent opening in
appliance and mark location on wall.
2. Use saw to cut opening in wall. Cut a 2-1/2 to 3 inch
(64-76mm) opening on inside wall and a 3 to 3-1/2 inch
(76-89mm) opening on outside of house.
3. Use hose clamp to secure flex pipe to collar assembly
(Figure 21.3).
4. Slide trim ring over flex pipe and run pipe through wall.
5. Attach hose to outside termination cap with second
hose clamp.
6. Secure termination cap to outside surface.
7. Secure trim ring to interior wall.
Never draw outside combustion air from:
Wall, floor or ceiling cavity
Enclosed space such as an attic or garage
Leveling Bolt
Attach Termination
Cap to Exterior Wall