CASTILE INSERT
E. Hearth Extension
Use a non-combustible ember floor protector, extending
beneath the appliance and to the front, and to the sides as
indicated in Floor Protection below.
F. Floor Protection
B
C
Figure 12.1
Minimum Floor Protection
Dimensions
Front Width
(Steel Panel Set)
A
Front Width
(Cast Panel Set)
Depth
(Steel Panel Set)
B
Depth
(Cast Panel Set)
C
Floor Protection Depth
D
Floor Protection Width
Table 12.1
G. Installation into a Factory-Built Fireplace
The following modifications are permissible:
-
Removal of damper or locked in open position
-
Removal of smoke shelf or baffle
-
Removal of ember catches
-
Removal of fire grate
-
Removal of view screen/curtain
-
Removal of doors
-
Removal of factory-built fireplace floor
External trim pieces which do not affect the operation
of the fireplace may be removed providing they can be
stored on or within the fireplace for reassembly if the
insert is removed.
The permanent metal warning label provided must
be attached to the back of the fireplace, with screws
or nails, stating that the fireplace may have been
altered to accommodate the insert, and must be
returned to original condition for use as a conventional
fireplace (Figure 12.2).
12
A
D
Inches
Millimeters
28-3/8
540
28-1/4
721
13-3/8
718
13-1/8
606
14
356
32-3/8
822
THIS FIREPLACE MAY HAVE BEEN ALTERED
TO ACCOMMODATE AN INSERT. IT MUST BE
RETURNED TO ITS ORIGINAL CONDITION
BEFORE USE AS A SOLID FUEL BURNING
FIREPLACE.
Figure 12.2
Heath & Home Technologies
250-2061
5.5 in. width x 2 in. height
If the hearth extension is lower than the fireplace
NON. ANOD. ALUM BLACK LETTERS ON SILVER
opening, the portion of the insert extending onto the
with 1/8 in. holes on both sides.
Black letters
hearth must be supported.
Manufacturer designed adjustable support kit can be
ordered from your dealer.
NOTE: Refer to chimney liner manufacturer for
recommendations on supporting the liner.
Installation into fireplaces without a permit
will void the listing.
The firebrick (refractory), glass doors, screen rails,
screen mesh and log grates can be removed from a
factory-built firebox in order to gain minimum insert
opening requirements.
Any smoke shelves, shields and baffles may be
removed from a factory-built firebox if attached with
mechanical fasteners.
The metal floor of the factory-built firebox may be
removed to facilitate the installation of the insert only
when a 1 inch (25mm) airspace is provided between
the insert and the floor of outer wrap.
The following is only one example as there are many
different models of factory-built fireplaces.
NOTE: This example is for reference only. Any
modifications must not compromise the
structural integrity or reduce the protection for
combustible materials.
Mark area of
floor to cut
Figure 12.3
7022-801H
WARNING
Starter hole
250-2061
250-2061
06/21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Castilei-pmh-cCastilei-twl-c