6.2 NORMAL OPERATION

FOR SAFETY REASONS THE DOOR OF THE HEARTH CAN BE OPENED ONLY FOR LOAD THE FUEL.
THE HEARTH DOOR MUST ALWAYS REMAIN CLOSED DURING OPERATION OR REST.
WHEN FUEL IS ADDED ONTO THE EMBERS IN THE ABSENCE OF A FLAME, A CONSIDERABLE AMOUNT OF FUMES
MAY DEVELOP. IF THIS HAPPEN, AN EXPLOSIVE MIXTURE OF GAS AND AIR MAY FORM, AND IN EXTREME CASES AN
EXPLOSION MAY OCCUR. FOR SAFETY REASONS IT IS ADVISABLE TO PERFORM A NEW LIGHTING PROCEDURE WITH THE
After having positioned the registers correctly, insert the indicated hourly wood load avoiding overloads that cause anomalous stresses and
deformations (according to the instructions on paragraph TECHNICAL DESCRIPTION).
YOU SHOULD ALWAYS USE THE PRODUCT WITH THE DOOR CLOSED IN ORDER TO AVOID DAMAGES DUE TO OVERHEATING
(FORGE EFFECT). THE INOBSERVANCE OF THIS RULE MAKES THE WARRANTY EXPIRE.
FOR SAFETY REASONS THE DOOR OF THE APPLIANCES MUST BE OPENED ONLY FOR THE LOADING OF THE FUEL OR FOR REMOvING
THE ASHES, WHILE DURING THE OPERATION AND THE REST, THE DOOR OF THE HEARTH MUST REMAIN CLOSED.
With the controls positioned on the front of the appliance it is possible to adjust the heat emission of the hearth. They have to be
opened according to the calorific need. The best combustion (with minimum emissions) is reached when, by loading the wood, most
part of the air for combustion flows through the secondary air register.
NEVER OVERLOAD THE APPLIANCE (SEE THE HOURLY WOOD LOAD IN THE TABLE HERE BELOW). TOO MUCH FUEL AND TOO MUCH
AIR FOR THE COMBUSTION MAY CAUSE OvERHEATING AND THEN DAMAGE THE STOvE. YOU SHOULD ALWAYS USE THE APPLIANCE
WITH THE DOOR CLOSED IN ORDER TO AvOID DAMAGES DUE TO OvERHEATING (FORGE EFFECT). THE INOBSERVANCE OF THIS RULE
MAKES THE WARRANTY EXPIRE.
The adjustment of the registers necessary to reach the rated calorific yield with a depression at the flue of 12 Pa 1,2mm of column of
water) is the following one: see chapter TECHNICAL DESCRIPTION. The appliance works as an intermittent operating appliance.
Besides the adjustment of the air for the combustion, the intensity of the combustion and consequently the thermal performance of
the device is influenced by the flue. A good draught of the stack requires a less adjustment of air for combustion, while a poor draught
requires a more precise adjustment of air for combustion.
To verify the good combustion, check whether the smoke coming out from the flue is transparent.
If it is white, it means that the device is not properly adjusted or the wood is too wet; if instead the smoke is gray or black, it signals that
the combustion is not complete (it is necessary a greater quantity of secondary air).

6.2.1 USE OF THE OVEN

Place the smoke controller in the position USE OF THE OvEN (see chap. TECHNICAL DESCRIPTION)
Thanks to the air flow for the combustion, the temperature of the oven may become remarkably affected. A sufficient flue of the
chimney and of the channels, well cleaned for the flow of burning smokes around the oven are fundamental for a good cooking result.
Thick cakes and big roasts must be introduced in the lowest level. Flat cakes and biscuits must reach the medium level. The upper level
may be used to heat or grill.
The oven pan and the chrome plated oven grille may be located on different plans (see chapter Technical Description - ACCESSORIES).
When cooking food with high humidity, cakes with fruit or fruit itself, water of condensation will be produced. During the cooking
process some water vapour in the form of drops of condensed water can deposit onto the top and the side of the door. It is a physical
phenomenon.
By opening the door briefly and carefully (1 or 2 times, or even often in case of longer cooking times) you can let out the steam from
the cooking compartment and reduce condensation significantly.

6.2.2 OPERATION IN TRANSITION PERIODS

During transition periods when the external temperatures are higher, if there is a sudden increase of temperature it can happen that
the combustion gases inside the flue cannot be completely sucked up.
The exhaust gases do not come out completely (intense smell of gas). In this case, shake the grilling of the brazier more frequently and
increase the air for the combustion. Then, load a reduced quantity of fuel in order to permit a rapid burning (growing up of the flames)
and the stabilization of the draught. Then, check that all openings for the cleaning and the connections to the flue are air-tigh.
IN CASE OF DOUBT, DO NOT OPERATE THE PRODUCT.